1.5MW/1500kw Gas Generator Set for Biogas (Low Voltage - 400V) 50Hz

Product Details
Customization: Available
Output Type: AC Three Phase
Gas Source: Biogas
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (28)
Find Similar Products

Basic Info.

Model NO.
LY1600GL-Z
Power
>200kW
Standard
Standard
Specification
15000KG
Origin
China

Product Description

LY1600GL‐Z Biogas Low Voltage Genset Technical Parameters 50Hz
NOX≤500mg/Nm³1)
Minimum Low Heating Value (LHV) Min: 5.0 KWh/Nm³                           Sewage Treatment Biogas (65% CH4, 35% CO2)
Biological Biogas (60% CH4, 32% CO2, others N2)                                 Landfill Biogas (50% CH4, 27% CO2, others N2)
The data is for reference only, and the actual data shall be subject to the calculation of gas composition of the project
 
Engine Model LY16V170-Z
Engine power2)   kW 1548
Rated rotation speed   r/min 1500
Average effective pressure   MPa 1.75
Exhaust gas temperature   ºC ≤500
Wet exhaust flow About kg/h 7852
Combustion air flow ±8% kg/h 6978
Inlet air temp after intercooling ±5 ºC 50
Ventilation volume3) About kg/h 38047
Engine Technical Parameters  
Bore/Stroke   mm 170/195
Displacement   dm3 70.8
Average piston speed   m/s 9.75
Lubricant capacity 4)   dm3 240
Lubricant consumption rate with 100% load   g/kWh ≤0.3
Alternator  
Efficiency5)   % 96.9
 Energy Balance LY1600GL-Z
Output electric power 5)   kW 1500
High temp coolant heat ±8% kW 898
Low temp coolant heat ±8% kW 125
Heat of exhaust gas cooled to 150 ° C ±8% kW 764
Radiated heat from the engine About kW 52
Radiated heat from the alternator About kW 48
Gas consumption ±5% kW 3685
Electrical efficiency   % 40.7
Thermal efficiency   % 45.1
Total efficiency   % 85.8
 System Parameters  
Min/Max flow of high temp coolant   m3/h 52/66
Engine Kvs value 6)   m3/h 46
Flow of low temperature coolant   m3/h 40
Intercooler Kvs value 6)   m3/h 72
Engine coolant capacity   dm3 151
Intercooler coolant capacity   dm3 52
High temp coolant temperature inlet/outlet   ºC 76/89
Low temp coolant temperature inlet/outlet   ºC 46/49
Max exhaust back pressure   kPa 5
Max pressure drop before the air filter   kPa 0.5
Gas pressure range   kPa 5~15
Startup method and battery capacity     Electric startup & DC24V@360Ah
1) Exhaust gas emission: Oxygen content 5%, dry exhaust gas, NOx≤500mg/Nm3
2) Engine power rating is based on ISO 3046/1 standard
3) The amount of ventilation air at Delta T=15K, including the amount of combustion air
4) Piping and lubricant heat exchangers are excluded
5) Frequency 50Hz, voltage 400V, power factor is 1.0
6) The Kvs value refers to the flow rate with a pressure loss of 1 bar
This data is for reference only and is not intended to be a binding value. Please refer to the information in the technical agreement.
 
 Genset Model     LY1600GL-Z
 Dimensions      
 Length   mm 6820
 Width   mm 1700
 Height   mm 2615
 Net weight   kg 15000
       
 Noise
Sound power level Multiplie Hz 32 63 125 250 500 1000 2000 4000 8000
Exhaust noise 125 dB(A) 107 144 137 126 114 108 105 105 98
Unit noise 110 dB(A) 94 95 96 98 99 101 99 106 103
Exhaust gas noise at 1 meter, ±2.5 dB (A)
Unit side noise at 1 meter, ±1 dB (A)
 