Output Type: AC Three Phase
Gas Source: Natural Gas
Certification: ISO
Power: 1000kw
Standard: Standard
Weight: 13000kg
Customization:
Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
LY12V170-T (HV)
Voltage Level
10500V
Transport Package
Break Bulk Ship
Specification
5300*1700*2300
Trademark
Liyu
Origin
China
HS Code
8502200000
Production Capacity
500

Product Description

LY1000GH-T Natural Gas High Voltage Genset Technical Parameters 50Hz
NOX≤500mg/Nm³1)
Minimum Methane Value: MN80
Engine Model LY12V170-T
Engine power2)   kW 1035
Rated rotation speed   r/min 1500
Average effective pressure   MPa 1.58
Exhaust gas temperature   ºC ≤550
Wet exhaust flow About kg/h 5448
Combustion air flow ±8% kg/h 5268
Inlet air temp after intercooling ±5 ºC 50
Ventilation volume3) About kg/h 29308
Engine Technical Parameters  
Bore/Stroke   mm 170/195
Displacement   dm3 53.1
Average piston speed   m/s 9.75
Lubricant capacity4)   dm3 180
Lubricant consumption rate with 100% load   g/kWh ≤0.4
Alternator  
Efficiency5)   % 96.6
Energy Balance LY1000GH-T
Output electric power5)   kW 1000
High temp coolant heat ±8% kW 598
Low temp coolant heat ±8% kW 98
Heat of exhaust gas cooled to 120 ° C ±8% kW 572
Radiated heat from the engine About kW 43
Radiated heat from the alternator About kW 34
Gas consumption ±5% kW 2531
Electrical efficiency   % 39.5
Thermal efficiency   % 46.2
Total efficiency   % 85.7
System Parameters  
Min/Max flow of high temp coolant   m3/h 40/56
Engine Kvs value6)   m3/h 42
Flow of low temperature coolant   m3/h 35
Intercooler Kvs value6)   m3/h 30
Engine coolant capacity   dm3 111
Intercooler coolant capacity   dm3 28
High temp coolant temperature inlet/outlet   ºC 78/92
Low temp coolant temperature inlet/outlet   ºC 48/52
Max exhaust back pressure   kPa 5
Max pressure drop before the air filter   kPa 0.5
Gas pressure range   kPa 3-20
Startup method and battery capacity     Electric startup & DC24V@240Ah

1) Exhaust gas emission: Oxygen content 5%, dry exhaust gas, NOx≤500mg/Nm3
2) Engine power rating is based on ISO 3046/1 standard
3) The amount of ventilation air at Delta T=15K, including the amount of combustion air
4) Piping and lubricant heat exchangers are excluded
5) Frequency 50Hz, voltage 10500V, power factor is 1.0
6) The Kvs value refers to the flow rate with a pressure loss of 1 bar
This data is for reference only and is not intended to be a binding value. Please refer to the information in the technical agreement.
Genset Model LY1000GH-T
Dimensions      
Length About mm 5300
Width About mm 1700
Height About mm 2300
Net weight About kg 13000
 
Noise
Sound power level Multiplier Hz 32 63 125 250 500 1000 2000 4000 8000
Exhaust noise 120 dB (A) 109 115 122 121 118 110 109 107 106
Unit noise 103 dB (A) 96 101 95 96 96 97 96 95 97
                             
Exhaust gas noise at 1 meter, ±2.5 dB (A)
Unit side noise at 1 meter, ±1 dB (A)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
267
Year of Establishment
2009-08-07