Customization: | Available |
---|---|
After-sales Service: | Local Service Team |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Engine Model | LY12V170-T1 | ||
Enginepower | kW | 786 | |
Rated speed | r/min | 1500 | |
Average effective pressure | MPa | 1.18 | |
Exhaust gas temperature | ºC | ≤500 | |
Wet exhaust gas flow rate | About | kg/h | 4447 |
Combustion air flow rate | ±8% | kg/h | 4256 |
Intake temperature after | ±5 | ºC | 50 |
Ventilation capacity | About | kg/h | 26368 |
Engine technical parameters | |||
/Cylinder Diameter/Stroke | mm | 170/195 | |
Displacement | dm3 | 53.1 | |
Average piston speed | m/s | 9.75 | |
Lubricant capacity | dm3 | 180 | |
Average consumption rate of lubricant at full load | g/kWh | ≤0.3 | |
Alternator | |||
Efficiency | % | 95.4 | |
Energy Balance | LY1200GH-G | ||
5)Output electric power5) | kW | 750 | |
High-temperature coolant heat | ±8% | kW | 630 |
Low temperature coolant heat | ±8% | kW | 87 |
120ºC Exhaust gas cooling to 120°C heat | ±8% | kW | 424 |
Engine radiant heat | About | kW | 35 |
Heat radiated by the alternator | About | kW | 36 |
Gas consumption | ±5% | kW | 2095 |
Electricity efficiency | % | 35.7 | |
Thermal efficiency | % | 50.3 | |
Total efficiency | % | 86 | |
System Parameters | |||
/High temperature coolant min/max flow | m3/h | 35/55 | |
Kvs EngineKvsValue | m3/h | 42 | |
Low temperature coolant flow | m3/h | 35 | |
Kvs IntercoolerKvsValue | m3/h | 30 | |
Engine Coolant Capacity | dm3 | 111 | |
Intercooler coolant capacity | dm3 | 28 | |
/High temperature coolant temperature inlet/outlet | ºC | 76/89 |