Ly2000gh-Z 2MW Biogas High Pressure Generator Set

Product Details
Customization: Available
After-sales Service: Local Service Team
Warranty: 1 Year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (28)
  • Ly2000gh-Z 2MW Biogas High Pressure Generator Set
  • Ly2000gh-Z 2MW Biogas High Pressure Generator Set
  • Ly2000gh-Z 2MW Biogas High Pressure Generator Set
  • Ly2000gh-Z 2MW Biogas High Pressure Generator Set
  • Ly2000gh-Z 2MW Biogas High Pressure Generator Set
  • Ly2000gh-Z 2MW Biogas High Pressure Generator Set
Find Similar Products

Basic Info.

Model NO.
LY2000GH-Z
Output Type
AC Three Phase
Gas Source
Biogas
Certification
CE, EAC
Power
1804kw
Standard
Standard
Length(mm)
7450
Width(mm)
1700
Height(mm)
2750
Weight(Kg)
17000
Transport Package
Wooden Box
Trademark
Liyu
Origin
China
HS Code
8502200090
Production Capacity
800/Year

Product Description

LY2000GH-Z 2MW Biogas high pressure generator set technical parameters 50HZ
NOX ≤ 500mg/Nm³
 
Engine Model  LY20V170-Z
Enginepower    kW  1804
Rated speed    r/min  1500
Average effective pressure    MPa  1.63
Exhaust gas temperature    ºC  ≤500
Wet exhaust gas flow rate  About  kg/h 9297
Combustion air flow rate  ±8%  kg/h  8284
Intake temperature after  ±5  ºC 50
Ventilation capacity About  kg/h  45920
Engine technical parameters
/Cylinder Diameter/Stroke    mm  170/195
Displacement    dm3  88.5
Average piston speed    m/s  9.75
Lubricant capacity    dm3  300
Average consumption rate of lubricant at full load    g/kWh  ≤0.3
Alternator
Efficiency   97
Energy Balance  LY2000GL-Z
5)Output electric power5)    kW  1750
High-temperature coolant heat  ±8%  kW 1111
Low temperature coolant heat  ±8%  kW  129
120ºC Exhaust gas cooling to 120°C heat  ±8%  kW  894
Engine radiant heat  About  kW  67
Heat radiated by the alternator  About  kW  54
Gas consumption  ±5%  kW  4375
Electricity efficiency    40
Thermal efficiency    45.8
Total efficiency    85.8
System Parameters
/High temperature coolant min/max flow    m3/h  75/95
Kvs   EngineKvsValue    m3/h  46
Low temperature coolant flow    m3/h  50
Kvs IntercoolerKvsValue    m3/h  72
Engine Coolant Capacity    dm3  210
Intercooler coolant capacity    dm3  52
/High temperature coolant temperature inlet/outlet    ºC  76/89
 