Basic Info.

Model NO.
LY1600GH-G
Output Type
AC Three Phase
Gas Source
Blast Furnace Gas
Certification
CE, EAC
Power
1093kw
Standard
Standard
Length(mm)
6150
Width(mm)
1700
Height(mm)
2650
Weight(Kg)
15000
Transport Package
Wooden Box
Trademark
Liyu
Origin
China
HS Code
8502200090
Production Capacity
800/Year

Product Description

LY1600GH-G 1MW blast furnace gas high-pressure generator set/genset technical parameters 50HZ
NOX ≤ 500mg/Nm³
 
Engine Model  LY16V170-G
Enginepower    kW  1093
Rated speed    r/min  1500
Average effective pressure    MPa  1.23
Exhaust gas temperature    ºC  ≤500
Wet exhaust gas flow rate  About  kg/h 7001
Combustion air flow rate  ±8%  kg/h  2708
Intake temperature after  ±5  ºC 50
Ventilation capacity About  kg/h  30863
Engine technical parameters
/Cylinder Diameter/Stroke    mm  170/195
Displacement    dm3  70.8
Average piston speed    m/s  9.75
Lubricant capacity    dm3  240
Average consumption rate of lubricant at full load    g/kWh  ≤0.3
Alternator
Efficiency   96.1
Energy Balance  LY1600GL-G
5)Output electric power5)    kW  1050
High-temperature coolant heat  ±8%  kW 910
Low temperature coolant heat  ±8%  kW  89
120ºC Exhaust gas cooling to 120°C heat  ±8%  kW  764
Engine radiant heat  About  kW  48
Heat radiated by the alternator  About  kW  43
Gas consumption  ±5%  kW  3153
Electricity efficiency    33.3
Thermal efficiency    53.1
Total efficiency    86.4
System Parameters
/High temperature coolant min/max flow    m3/h  55/75
Kvs   EngineKvsValue    m3/h  46
Low temperature coolant flow    m3/h  40
Kvs IntercoolerKvsValue    m3/h  72
Engine Coolant Capacity    dm3  151
Intercooler coolant capacity    dm3  52
/High temperature coolant temperature inlet/outlet    ºC  76/89
 